Industrial Reliability Challenges Seen from the "Robot Marathon"

In April 2026, the Beijing Yizhuang Humanoid Robot Half Marathon continued to dominate the headlines — over 300 robots competed on the same course, with 120 running the full distance autonomously without remote control. The champion robot, "Lightning," crossed the finish line with a net time of 50 minutes and 26 seconds, nearly two hours faster than the previous year — even surpassing the men's half marathon world record for humans.

In today's rapidly evolving smart factory environment, robots are no longer isolated mechanical arms, but highly sophisticated electromechanical systems integrating a "brain" (controller), "limbs" (manipulators), and "senses" (vision/sensing). To support the vision of Industry 4.0, these robots must operate like marathon runners — achieving tens of thousands of hours of "zero-failure" operation under conditions filled with electromagnetic interference, harmonic noise, and thermal drift. As a senior EMC application expert at Leiditech, I fully understand that this "marathon-style" operation imposes near-extreme demands on system reliability.

The complexity of industrial robots depends on their axis configuration and task management. The six common core robot types include:

· Articulated robots: Simulate the human arm with multi-axis rotational capability.

· SCARA (Selective Compliance Assembly Robot Arm): Designed for high-speed assembly, featuring two parallel axes.

· Delta robots: Spider-like structure, excellent for high-frequency, precision pick-and-place tasks.

· Cartesian robots: Perform gantry-style motion along linear axes (X, Y, Z).

· Cylindrical robots: Combine rotary and linear motion, suitable for cylindrical workspaces.

· Spherical (polar) robots: Create a spherical work envelope through a combination of rotational and twisting axes.

Throughout the long lifecycle of these robots, any minor electromagnetic transient or electrostatic discharge (ESD) can cause the entire "race" to end prematurely. Therefore, building an impenetrable EMC defense line is a core element in ensuring industrial productivity.

Core Power Source: Servo Drive System and Power Stage Protection

The drive system is the heart of a robot. In a three-phase inverter architecture powered by 48V to 60V DC, high power density and compact PCB layout impose severe challenges on electrical protection. Particularly with the adoption of wide-bandgap semiconductors (such as SiC/GaN), switching frequencies have increased dramatically, and the system's requirement for common-mode transient immunity (CMTI) has crossed the 100V/ns threshold. In such high-slew-rate environments, our typical strategy at Leiditech is to use high-performance protection devices to safeguard the front end of isolated gate drivers, ensuring signal integrity.

 

Leiditech provides surge protection for 48V power interfaces. Depending on the power supply environment, selectable overcurrent protection devices include PTC resettable fuses, overvoltage protection TVS devices, and reverse polarity protection diodes. These meet IEC 61000-4-2 Level 4 requirements ( ±30kV contact discharge, ±30kV air discharge ). For compliance with high-level IEC 61000-4-5 surge testing, Leiditech's high-power devices are recommended.

In response to the specific risks in the servo drive power stage, Leiditech has developed the following targeted protection strategies:

Risk points (based on industrial design standards)

Leiditech Protection Strategy ("Transient Killer" Solution)

Overcurrent and power stage short circuit (per sections 2.2.5/2.2.10): Instantaneous massive surges caused by motor winding short circuits or power bridge arm breakdown.

Deploy ultra-fast response TVS diodes combined with high-side current monitoring circuits to clamp overvoltage within microseconds, protecting critical MOSFETs/IGBTs from avalanche breakdown.

Thermal damage and derating (per sections 2.2.7/2.2.9): Long-term overload operation causes temperature rise in power modules, reducing apparent load capability.

Integrate low-leakage ESD arrays and current-limiting devices to ensure precision temperature control circuits are not disturbed by electrical noise, keeping the power stage operating within its safe operating area (SOA).

Back EMF: High-voltage feedback surge generated during motor deceleration or braking.

Connect Leiditech high-power TVS arrays in parallel with the DC bus to precisely absorb inductive energy, preventing power circuit overstress damage caused by voltage overshoot.

Additionally, for motor drive and power interfaces, adopt PTC + high-power TVS protection to withstand overcurrent and overvoltage surges, meeting the power system requirements of humanoid robots.

The Robot's "Senses": ESD Suppression for Sensing and Radar Systems

 

Sensors are core components ensuring robotic motion accuracy and operational safety. The joint sensors of humanoid robots can achieve a measurement accuracy of ±0.025°. However, ESD can easily cause sensor signal anomalies, loss of stability, or even permanent chip damage.

Sensors endow robots with acute senses to perceive their environment. Millimeter-wave radar (mmWave), ultrasonic sensors, and vision processing systems are the core perception units. A comparison of the characteristics of various sensor types is as follows:

Characteristic

Millimeter-wave radar

Camera

Laser radar

Ultrasonic

Detection performance

Powerful, stable

Severely affected by lighting conditions

Extremely poor performance in adverse weather

Short range only

Environmental adaptability

Unaffected by rain, dust, or fog

Poor

Poor

Strong

Dark environment operation

Fully supported

Not supported

Not supported

Supported

To protect these sensitive "senses," Leiditech has designed ultra-low capacitance ESD devices for radar front-ends and signal interfaces. These devices effectively eliminate "electrical aging" or "electrical loss" caused by ESD interference, ensuring that sensor data does not experience thermal drift or deviation due to static charge accumulation. This not only improves the accuracy of visual feedback, but also maximizes the robot's apparent load capability by preventing long-term electrical degradation of the sensor signal chain.

1. Joint Encoder / Magnetic Sensor: Multi-channel integrated Leiditech ESD array SMC12, SOT-23 small package, suitable for compact joint space, compatible with SPI/I2C interfaces.

2. IMU / Force Tactile Sensor: Select ultra-low capacitance devices that do not affect weak signal acquisition, resisting contact and vibration-induced ESD.

3. Vision / Ultrasonic Radar: Adopt HDMI/MIPI/USB dedicated ESD device — Leiditech ULC3304P10LV, with capacitance as low as 0.15pF, without interfering with high-speed data transmission.

Leiditech has launched ESD diodes featuring small size, high current capability, and ultra-low capacitance, suitable for high-density interfaces:

· For interfaces such as joint sensors, IMU, SPI/I2C/CAN-FD/MIPI, etc., select devices including the ESDA33CP30 (DFN1006), ULC3304P10LV (DFN2510), SMC24LVQ (SOT-23), etc. These save more than 50% of PCB area compared to traditional packages and comply with IEC 61000-4-2 ESD Level 4 ( ±8kV contact, ±15kV air discharge ).

· Sensor companion power supply: For 3.3V, use SMDA33CDN (DFN1006, IPP = 35A); for 5V, use PTVS0542H100 (DFN1006, IPP = 105A); for 12V, use SD1571P6W (DFN1610, IPP = 60A). These meet the requirements for power supply ESD and surge protection.

Stable Supply Station: Thermal and Electrical Protection for Battery Management Systems (BMS)

 

The endurance and safety of Autonomous Mobile Robots (AMRs) depend on the robustness of the Battery Management System (BMS). Lithium-ion batteries have stringent temperature range limitations:

· 充Charging limit: 0°C to 45°C (exceeding this range may cause battery pressure increase and venting).

· Discharge limit: -20°C to 60°C (high temperatures may cause risk of thermal runaway).

Leiditech's BMS reinforcement solution follows the principle of "thermal and electrical parallelism." For the peripheral circuits of protection ICs such as the BQ77905, we not only focus on precise temperature control based on the TMP303/390, but also deploy industrial-grade surge suppressors at the battery pack pins and charging ports. By suppressing the electrical surges generated during charging and discharging, we prevent false triggering and damage to the monitoring IC, ensuring stable power supply to the battery throughout the "marathon" and avoiding the potential 4-8% degradation in system efficiency caused by electrical overstress.

Neural Network: A Robust Defense Line for Industrial Communication Buses

Under the Industry 4.0 architecture, communication both within the robot and between nodes (such as RS-485 and Industrial Ethernet) faces strong interference from inverter switching noise. High-precision encoder feedback protocols such as EnDat 2.2, BiSS, and Tamagawa, in particular, impose near-stringent requirements for EMC immunity.

To establish a defense line for the robot's "neural network," Leiditech provides an industry-leading three-stage protection architecture for interfaces such as RS-485:

1. 1. Leiditech Industrial-Grade Protection Solution for RS-485:

 

· Stage 1 (Primary defense line): Ceramic gas discharge tube (GDT) 3R090-5S, responsible for discharging high-energy lightning strikes or severe surges intruding from the power supply.

· Stage 2 (Energy coupling): Select high-precision PTC resettable fuse SMD1812P050TF or dedicated coordination resistors to achieve inter-stage decoupling and limit instantaneous current.

· Stage 3 (Fine protection): Select Leiditech's low-capacitance, high-clamping-efficiency TVS diode SM712 to precisely lock the residual voltage within the processor's safe voltage range, ensuring "absolute silence" in signal transmission under strong noise environments.

2. 2. CAN-FD High-Speed Bus Protection: For the CAN-FD bus, Leiditech selects the SMC24LVQ (SOT-23) ESD device, with capacitance less than 5pF. It ensures signal integrity while filtering out noise and passing ESD testing. It meets IEC 61000-4-2 Level 4 ( ±30kV contact discharge, ±30kV air discharge ), ensuring stable high-speed communication and meeting the communication requirements for autonomous operation of humanoid robots.

 

 

3. Industrial Ethernet: This Leiditech solution is designed for surge protection of 1000M Gigabit Ethernet ports in outdoor environments. A two-stage protection architecture is recommended, offering stable and reliable operation and effectively ensuring signal integrity under high-temperature conditions. It complies with IEC 61000-4-2 Level 4 ( ±30kV contact discharge, ±30kV air discharge ) and meets IEC 61000-4-5 requirements (10/700μs waveform, 40Ω impedance, 6kV voltage, 5 positive and 5 negative tests). Signal transmission remains stable under high-temperature conditions with no packet loss.

 

Leiditech Recommended Part Numbers for Robot ESD and Surge Protection

Part number

Core parameters

Package

Protection location

SMBJ58CA

58V,600WBidirectional,6.4A

SMB

48V Primary power protection

SMAJ58CA

58V,400WBidirectional,4.3A

SMA

SMDJ58CA

58V,3000WBidirectional,32A

SMC

SMF58CA

58V,200Bidirectional,2A

SOD-123FL

SMBJ15CA

15V,600W,Bidirectional,24.6A

SMB

12VSecondary power protection

SMF15CA

15V,200W,Bidirectional,8.2A

SOD-123FL

SMBJ18CA

18V,600W,Bidirectional,20.6A

SMB

MOSFET Gate protection

SMC12

12V,Bidirectional,35pF

SOT-23

SPI ESD protection

SMC24LVQ

24V,Bidirectional,5pF

SOT-23

CAN-FD Bus ESD protection

SD05C

5V,Bidirectional11pF

SOD-323

5V Sensor power protection

GBLC03C

3.3V,Bi,0.6PF

SOD-323

Gigabit signal ESD protection

ULC3304P10LV

3.3V,Unidirectional,0.28PF

DFN2510P10

MIPI / HDMI interface ESD protection

SMDA33CDN

3.3V,Bidirectional,35A

DFN1006

3.3V Power supply ESD and surge protection

PTVS0542H100

5V,Bidirectional,105A

DFN1006

5V Power supply ESD and surge protection

SD1571P6W

15V,Unidirectional,60A

DFN1610

12V Power supply ESD and surge protection

3R090-5S

90V,5KA

3R 5mm

Interface ESD and surge protection

SM712

7/12V,Bidirectional,45pF

SOT-23

SMD1812P050TF

15V,0.15Ω,0.5A

SMD1812

Conclusion: Leiditech Enables Long-Term Operation for Industry 4.0

On the track of the robot "marathon" and on the stage of Industry 4.0, a system's apparent load capability and operational lifespan are the only hard currency for measuring competitiveness. Every electromechanical connection point and every sensing link is a potential EMC weak link.

As an electromagnetic compatibility protection expert, Leiditech is committed to pushing the performance of leading hardware platforms such as TI to their peak. Our protection solutions are not merely a "stacking of components," but a "shield" tailored specifically for robotic systems. On the track of the robot "marathon," Leiditech is the solid shield ensuring "zero downtime" for the system. Reliability is the cornerstone of industrial intelligence, and Leiditech is the unbreachable wall protecting that cornerstone.

Laisser un commentaire

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués. *
Nom
Email
Contenu
Code de vérification
ver_code