ISO 21498-2:2024 New Regulation Part 2: How to Upgrade EMC Protection for High-Voltage Components — Taking OBC as an Example
Preface
"ISO 21498-2:2024 New Regulation Interpretation Part 1" covered what has changed in ISO 21498-2:2024. What needs to be clarified is that the standard itself does not directly modify any technical requirements, test methods, or pass/fail criteria for EMC protections such as EFT/ESD/Surge — these verifications are still covered by relevant standards such as ISO 7637, ISO 11452, CISPR 25, and UN R10. What is truly critical is that the new version strengthens the full-spectrum constraints on the operating characteristics of high-voltage systems, and these parameters are precisely the prerequisites for EMC protection design. If the protection solution is not adapted accordingly, it will fail the new version's collaborative verification.
This article takes a 400V platform 6.6kW OBC (On-Board Charger) as an example to break down the upgrades to Leiditech's EMC protection solution before and after the implementation of the new standard, and analyzes the four logical links between the upgrade and the new standard, providing a reference for component R&D engineers.
I.Comparison of OBC solutions before and after implementation
1.1 Typical solution before implementation
Before the implementation of the new standard, the mainstream Leiditech recommended solution for the 6.6kW OBC high-voltage components was as follows:
· F1/F2 Fuses: 500VDC / 275VAC 50A
· G1 Gas Discharge Tube (GDT): 2R2500T-8 (DC spark voltage 2.5kV)
· RV1–RV3 Varistors (MOV): 20D471K
· D1 TVS: SMBJ400CA (600W)
· D2 TVS: SMCJ440CA (1500W)
1.2 Post-implementation upgrade solution
After the implementation of the new standard, the upgraded Leiditech solution includes the following key updates:
· D1 upgraded to Leiditech SMCJ400CA (1500W)
· D2 upgraded to 5.0SMDJ440CA (5000W)
· DC-Link capacitor voltage rating increased from 450VDC to 600VDC
1.3 Three key upgrades
Surge protection TVS: PFC input side upgraded from small-package SMA/SMB 400–600W to large-package SMC ≥1500W; isolated DC/DC high-voltage output side upgraded from ≤1500W to ≥5000W.
EMC filter: Upgraded from a single kHz–MHz common-mode choke + single μF-class X capacitor + two nF-class Y capacitors to a π-type filter network with dual common-mode chokes (high and low frequency combined) + dual X capacitors + an additional set of Y capacitors, improving both high and low frequency filtering performance.
DC-Link capacitor: Voltage rating upgraded from 450VDC to 600VDC.
Shanghai Leiditech’s upgrade solution simultaneously addresses all three areas. Leiditech EMC engineers can also provide one-on-one selection reviews to ensure compliance with the 2024 edition collaborative verification.
II.Four dimensions of correlation analysis
2.1 Higher short-circuit withstand capability requirements for EMC protection components
The newly added short-circuit test (Clause 6.12) in the 2024 version verifies the effectiveness of the protection/isolation action and the safety performance of the component itself when the output terminals of a high-voltage component are accidentally short-circuited. During the test, the circuit generates a transient short-circuit current with a long duration and extremely high energy, with the peak current reaching more than 10 times the rated operating current. Although the EMC protection components installed at the high-voltage ports do not directly discharge the short-circuit current, they must still withstand the extremely high transient energy impact of the short-circuit event, maintaining complete characteristic parameters without short-circuit, open-circuit, fire, or cracking. Products certified under the previous version typically did not consider this stress condition in their protection component selection.
2.2 The parasitic parameters of EMC protection circuits need to be matched more precisely.
The 2024 version substantially revises the ripple test: adjusting the test frequency range, specifying ripple current monitoring, and tightening the impedance matching requirements for the test environment. The core logic is to make the laboratory environment more closely reflect the high-frequency impedance characteristics of high-voltage cables under actual vehicle operating conditions. After the protection circuit is connected, its parasitic inductance and capacitance inevitably affect the actual port impedance. Poor matching can directly cause ripple test results to exceed limits, and can even introduce additional resonance and voltage amplification. The new version incorporates this matching quality into the assessment criteria.
2.3 Higher requirements for the coordinated performance of EMC protection components.
The 2024 version strengthens constraints on dynamic operating parameters: adding voltage slope immunity limits, clarifying load dump voltage change rate monitoring, and tightening transient overvoltage amplitude limits. This requires protection components at all stages to complete coordinated action within a shorter time, clamp residual voltage to a lower level, and ensure that the protection circuit does not increase the voltage change rate when connected. Products certified under the previous version may have insufficient coordination margins between protection stages, leading to increased residual voltage due to gaps in coordinated response under dynamic conditions, or parasitic resonance amplifying overvoltage.
2.4 Higher requirements for the consistency of EMC protection component parameters.
The 2024 version increases the requirements for test reproducibility and consistency, ensuring that results for the same component from different laboratories are comparable. If the parasitic parameters, trigger voltage, and clamping voltage of protection components exhibit large dispersion in mass production, it will directly affect the stability of port impedance, causing ripple test results to exceed dispersion limits. The new version incorporates parameter consistency into the assessment criteria, requiring that critical parameters maintain very small dispersion in mass production.
III.Mapping to OBC actual test items
3.1 Clause 6.12 Short circuit test
Requirement: The OBC must not create a hazard when the 400V high-voltage DC charging output terminals are short-circuited. This requires the isolated DC/DC output filter capacitors and the input DC-Link capacitors to have:
· Higher voltage margin (600VDC minimum)
· Self-healing characteristics
· Fail-open mode
Additionally, the TVS on the 400V high-voltage DC charging output side and the TVS on the PFC input side must have higher peak pulse power and Ipp capability.
3.2 Clause 6.3 Ripple emission (AN revision)
After the Annex C artificial network revision and the unification of the 50mΩ source impedance, the load for the OBC ripple emission test under Clause 6.3 (simulating the battery pack source impedance) is unified to a low impedance (the old version also had a 100mΩ configuration). The test is stricter, the load is heavier, and the ripple emission is more severe. This requires the DC/DC output filter capacitors and DC-Link capacitors to have stable low parasitic parameters/low impedance characteristics across the entire 100Hz–150kHz frequency band; the TVS parasitic capacitance must also be controlled at a low level to avoid affecting the overall ripple suppression of the chain.
3.3 Clause 6.5 Ripple immunity
The combination of "ripple immunity adds current limit values" + "Table B.4 example current limit values" + "frequency lower limit changed to 100Hz" + "6V minimum level," along with the unified AN impedance to a low source impedance, makes the ripple immunity test under Clause 6.5 more severe. The ripple current stress on the filter capacitors, DC-Link capacitors, and TVS on the OBC DC high-voltage charging output chain is more clearly defined and more stringent. This requires the filter capacitors and DC-Link capacitors to have lower ESL (to reduce high-frequency resonance) and better damping characteristics. The low dynamic resistance (Rd) and low clamping characteristics of the TVS on both the output and input sides become critical.
IV.Leiditech corresponding component upgrade recommendations
|
Location |
Before upgrade |
After upgrade (Leiditech recommended) |
Leiditech model |
|
PFC input side TVS |
SMBJ400CA 600W |
SMCJ400CA 1500W |
Leiditech SMCJ400CA |
|
Isolated DC/DC output side TVS |
SMCJ440CA 1500W |
5.0SMDJ440CA 5000W |
Leiditech 5.0SMDJ440CA |
Conclusion
Under the new standard, EMC protection for high-voltage components is not about "adding a few more components," but rather about systematically adapting to the four dimensions of short-circuit tolerance, parasitic matching, coordinated clamping, and batch consistency. Based on years of accumulated EMC protection technology, Leiditech provides complete solutions from component selection, helping component R&D engineers pass ISO 21498-2:2024 collaborative verification in a single attempt, shortening development cycles and reducing rectification costs.
#ISO21498-2 #OBC #OnBoardCharger #EMCProtection #SurgeProtection #TVSdiode #Leiditech #ShanghaiLeiditech #LEIDITECH #NewEnergyVehicles
Laisser un commentaire
- PoE power supply methods and EMC protection in the DC power supply system of intelligent logistics robots
- EMC protection design for access control security devices: the four external interfaces that deserve the most attention
- From power to antenna: EMC protection design solution for video doorbells
- Solving lightning and ESD hazards in industrial sites: LVDT pressure transmitter protection design
- Micro PLC crashes, resets, and communication packet loss? EMC is the root cause.